RELEASE NOTES

****************************************************
GageScope(r) Version 3.84.44.1928
****************************************************

----------------------------
Sections in this document:
----------------------------

Enhancements
Bug fixes
Known Bugs

About GageScope
Minimum System Requirements
Currently Supported Instruments
Currently Supported Driver Versions
Plug-Ins
Saving and Loading Setups
Deep Memory Support Enhancements
GageScope Professional Trial
Using GageScope without CompuScope Hardware
GageScope Lite Edition
How to Install GageScope 3.84
Known Installation Bugs in GageScope 3.84

How to Reach GaGe

* Note: It is highly recommended that this version of 
        GageScope be used with the most recent 
        version of the CompuScope driver.


-----------------------------------------------------
BUG FIXES 
-----------------------------------------------------

* Fixed the problem of wrong frequencies in FFT view when capturing data
  using external clock pingpong 
* Some minor bug fixes.

-----------------------------------------------------
KNOWN BUGS
-----------------------------------------------------

*  In some circumstances, the display scroll bars
   may disappear when loading a saved configuration
   while GageScope is in full screen mode.

*  Gagescope cannot display the preview information
   for the SIG files larger than 4 GBytes.

*  The PreTrigger edit box on GageScope GUI always
   shows the value entered by the user even if it is
   out of the range supported by the CompuScope
   card. GageScope will however coerce this value 
   and the acqusition will be performed with the 
   correct value of PreTrigger.
  
*  When saving file with a DC offset using EON cards,
   saved data can be corrupted.

*  Single channel CSUSB devices have a continuity
   issue when capturing more than the DMB buffer.

*  Mulrec captures that exceed the DMB buffer size 
   will force a trigger timeout on the later records.
   Set Trigger Timeout to Infinite to get around 
   this issue.

*  The trigger timeout field value is not saved in 
   the configuration file if the trigger mode is set 
   to Normal.

*  When restoring the configuration of multiple 
   cards, clicking on the black signal display will 
   speed up the loading of the different dialogs.

*  The General and Setting tab settings are not saved 
   in the configuration file.

*  When using complex triggering with a Razor 
   Master/Slave set, the board will sometimes not 
   respond to the trigger.  To fix the issue, abort 
   the capture and restart the capture.

*  Sometimes, the signal display will stop being 
   refreshed.  The user needs to close GageScope and 
   restart it to get the display to refresh again. 

*  There is a 2 GigaSample limit to reading the 
   correct trigger address of a saved Sig file.  The 
   user can still load in Sig files larger than 
   2 GS but figuring out the section to load in 
   could be confusing. Such files, however, are 
   stored correctly.

*  There may be a discrepancy between the displayed 
   DC offset and the actual DC offset when using a 
   EON card in the +/- 5 volt range.

-----------------------------------------------------
ABOUT GAGESCOPE
-----------------------------------------------------

Welcome to GageScope 3.8, the new generation of 
PC-based and traditional data acquisition, analysis, 
creation, monitoring, and control software from GaGe.
GageScope 3.8 combines advanced data acquisition and 
storage capabilities with time and frequency domain 
analysis as well as high-speed display to computer 
screen, all without having to write a single line of 
programming code!

GageScope 3.84 has the power to meet the needs of a 
wide variety of applications. GageScope 3.84 software 
provides a communication link between a personal 
computer (PC) and selected data acquisition and 
generation products from GaGe.

* No Programming Required - Works Out of the Box.
  GageScope brings all of the advantages of the 
  Pentium processor, Windows operating system and the 
  Internet to the CompuScope cards without requiring
  the user to write a single line of programming code 
  or draw diagrams.  It works straight out of the 
  box!

* Automatic Detection of CompuScope Cards.
  GageScope automatically detects the presence of 
  CompuScope cards in the system, bringing true 
  Plug-n-Play functionality to the Test and 
  Measurement user.

* Simple Interface, Complete Control.
  Change such settings as sample rate, trigger depth, 
  timebase, input range, and so on, with a click of 
  the mouse. All options are viewable on-screen 
  instead of in menus and dialog boxes.

* Dynamic Display.
  Adjustments made to any GageScope settings are 
  automatically reflected in the Display Window. 
  Change the sample rate, channel mode, timebase, 
  vertical scale, and other settings on the fly.

* Use Deep Memory Zoom to fully Zoom In and Out of 
  long data acquisitions.  Deep memory acquisition 
  really comes to life with zooming capability of 
  GageScope.  You can view the entire record (up to 
  2 GigaSamples) and then zoom in on the area of 
  interest.  Click on the Zoom tool, select the 
  portion of the signal that is of interest to you 
  and Zoom In to a specific sampling range.

* Scroll through the Signal using familiar Windows 
  scroll bars.  Now you don't have to scroll 
  through large sets of data using a slow and 
  ineffective scroll knob on a traditional DSO.  
  You can use standard Windows horizontal and 
  vertical scroll bars to view different portions 
  of the signal.

* Import Signals into Reports and Manuals.
  Capturing signals in the Windows environment 
  allows you to effortlessly bring the waveform 
  plots into word processing documents such as 
  project reports and product manuals.

* Remote Control of your CompuScope Cards.
  GageScope can be run remotely using standard 
  Windows utility programs.  This allows you control 
  over your CompuScope cards even when you are not 
  physically in the laboratory.

* Simultaneous Time and Frequency Domain Display.
  Now you can view captured signals in both time and 
  frequency domain using the powerful FFT 
  capabilities of GageScope.

* Save Signals and Setups to Disk.
  A virtually infinite number of signals can be 
  saved using GageScope. Saving signal files in 
  binary or ASCII format allows you to post-process 
  the data using analysis packages such as MATLAB, 
  Excel,  Mathcad etc. Setup files can also be saved, 
  allowing you to easily go back to a previously set 
  up experiment.

* InfoView.
  Not only does GageScope allow you to capture 
  signals and make measurements,  it also provides 
  results which can be displayed in the InfoView 
  window on the screen.

* Flexible Printing.
  If you use GageScope, you can print to any 
  Windows compatible printer or fax, including 
  network devices, to get a hard copy of your 
  measurements.

* Free File Viewing Capabilities.
  Signal files saved by GageScope can be viewed by 
  your colleagues on as many different stations as 
  you desire, using the Demo version of GageScope
  (installed from the CD or downloadable from 
  www.GageScope.com).

* Independent Timebase and Sample Rate.
  Have you ever wanted to capture a signal at a very 
  fast sample rate, but view it with a long timebase?  
  CompuScopes with deep memory are capable of doing 
  so, but many DSOs are not.  GageScope allows you to 
  decouple sample rate from timebase for more 
  flexible measurements.

* Independent Vertical Scale and Full Scale Input 
  Range.
  Almost all oscilloscopes on the market assume that 
  the signal they are measuring does not have enough 
  dynamic range to acquire more than 8 divisions 
  (256 rows of pixels across 8 divisions) on the 
  oscilloscope screen.  While this is true for an 
  8-bit DSO, it is not so for CompuScope cards which 
  can have as much as 16 bit resolution which would 
  require 65,536 pixel rows to do justice to the 
  dynamic range.

  As such, GageScope completely decouples Vertical 
  Scale from Full Scale Input Range, allowing the 
  user to scroll up and down on any vertical portion 
  of the signal.

* Unattended Transient Capture with Time and Date 
  Stamp.
  Optional AutoSave analysis tool for GageScope 
  allows completely unattended transient capture and 
  storage to disk.  A date and time stamp is also 
  included with the saved data for record keeping 
  purposes.

* Advanced Analysis Tools.
  GageScope advanced analysis tools currently include 
  Waveform Parameters, AutoSave, Averaging, FFT 
  Analysis, and the Extended Math. These analysis 
  tools dramatically enhance the functionality of 
  GageScope.


-----------------------------------------------------
MINIMUM SYSTEM REQUIREMENTS
-----------------------------------------------------

* PC with a Pentium 200 MHz processor; 266 MHz 
  Pentium II or higher strongly recommended
* Windows Vista , or Windows 7 operating system
* 64 MB RAM minimum; 128 MB RAM or more recommended 
  on all systems
* Hard disk: 20 MB to install the GageScope 
  application; 128 MB minimum free disk space 
  necessary for operation of the GageScope program
* Virtual memory under Windows XP and 2000: it is 
  recommended that you increase
  the Swap File Size by 128 MB to operate GageScope
* CD-ROM drive
* It is recommended to have a Windows Aero compliant
  video card
* 15-inch monitor 800 x 600 (Super VGA); 17-inch 
  1024 x 768 Ultra VGA recommended:  note that your 
  system must be set to 256 color display in order
  for the FFT capability to display results properly
* PC keyboard and 2-button mouse (3rd button, if present, 
  is not used)
* Internet Explorer 4.1 or higher; version 5.0 required 
  for full functionality
* The drivers for the CompuScope cards must be installed.


-----------------------------------------------------
CURRENTLY SUPPORTED INSTRUMENTS
-----------------------------------------------------

CompuScope Cards:
  CobraMax CompuScope(CScdG8 & CSEcdG8), Cobra
  CompuScope (CSXYG8 & CSEXYG8), BASE-8 cards (CScdG8),
  CS1250X, Eon CompuScope (CSCDG12), Eon Express
  CompuScope (CSE12XGY), Razor and Oscar CompuScopes
  (CS16XYY & CSE16XYY), Octopus CompuScope (CS8XXX &
  CSE8XXX), Octave CompuScope (CSE8XXX), CSUSB
  CompuScope and FCiX CompuScope..


-----------------------------------------------------
CURRENTLY SUPPORTED DRIVER VERSIONS
-----------------------------------------------------

CompuScope Drivers:
  5.00.50 and higher


-----------------------------------------------------
PLUG-INS
-----------------------------------------------------

What was formerly referred to as "Plug-Ins" are now 
included with the software and no longer offered as 
scalable modules for the GageScope Standard or 
Professional Edition packages.


-----------------------------------------------------
SAVING AND LOADING SETUPS
-----------------------------------------------------

GageScope now has the ability to restore the last 
configuration on start-up.  Users can now restore 
their last setup parameters.  GageScope will restore 
most of the System - Board - Channel - Display 
parameters settings.


-----------------------------------------------------
DEEP MEMORY SUPPORT ENHANCEMENTS
-----------------------------------------------------

Faster decimation:
                  GageScope now has improved the 
                  decimation algorithms for skip 
                  Sample and Mean Max for use on deep 
                  memory acquisitions resulting in 
                  increased display speeds and screen 
                  refresh rates.

Default MinMax decimation:
                  The default decimation method and 
                  factor have been modified to 
                  provide more meaningful information 
                  in decimated view; we now control 
                  the decimation factor via the 
                  Buffer Size.

Deep Memory Zoom: GageScope now offers the ability 
                  to select a portion of the 
                  decimated view and fetch the raw 
                  data from the board, thus 
                  displaying a variable-sized 
                  portion of the acquisition without 
                  decimation.

Deep Memory SplitFile Saving and Replay:
                  It is now possible to split a very 
                  large acquisition in as many files 
                  as the user wishes to create. This 
                  allows for easy transfer to other 
                  applications for analysis purposes, 
                  as well as playback in a fashion 
                  similar to MulRec and AutoSave 
                  Playback.

Save and Load Undecimated Data:
                  While it is still possible to save 
                  a very large file, it is now easier 
                  to re-load a selected portion of the 
                  saved file, effectively allowing the 
                  user to perform analysis using 
                  GageScope on any range of data from 
                  a deep memory capture.


-----------------------------------------------------
GAGESCOPE PROFESSIONAL TRIAL
-----------------------------------------------------
Customers may choose to run a FREE 21 day, 50 session 
Trial, which allows them access to all features of 
the Professional Edition for a limited time.

Please note that you will not be able to take 
advantage of the Professional Edition trial once you 
have installed the Lite or Standard editions.


-----------------------------------------------------
USING GAGESCOPE WITHOUT COMPUSCOPE HARDWARE
-----------------------------------------------------

Dynamic Demo Mode support has been removed from 
GageScope.  The CompuScope drivers now support the 
addition of CompuScope Virtual Systems, which are 
simulated CompuScope systems that may be accessed 
from all CompuScope application software.  
Consequently, Dynamic Demo Mode is no longer 
necessary since the user may install the CompuScope 
drivers, create a CompuScope Virtual System, and 
then simply run GageScope as usual.  For more 
information on installing a CompuScope Virtual System, 
please refer to your CompuScope PCI hardware
manual or the CompuScope driver readme.txt file.

The signals from a CompuScope Virtual System look and 
behave just like real input signals, allowing the user 
to perform operations and analysis on the signals.


-----------------------------------------------------
GAGESCOPE LITE EDITION
-----------------------------------------------------

GageScope Lite Edition is included for FREE with all 
purchases of CompuScope Analog Input Cards. In order 
to use the free GageScope Lite Edition, customers
need to register on-line at 
www.gage-applied.com/support/GageScope_download.php
to obtain this GageScope Lite Edition software key.  
Once the user has registered, the Lite Edition 
software key will be e-mailed to them.  A key cannot 
be obtained by contacting GaGe or its representatives 
by telephone, fax or email - customers must register 
on-line.

This edition contains limited functionality.

The limitations are listed as follows:

*	No saving and restoring of setup
*	Only ASCII file (signal) save is enabled
*	No Printing
*	No Waveform Analysis
*	No FFT or Math channels
*	No AutoSave and no AutoSave Playback
*	No Engineering Units
*	No Averaging
*	No SuperRes
*	No MulRec
*	No SubChannel
*	No Independent Trigger
*	No DMB Zoom functionality
*	No Cursors
*	No Multiple Displays of same signal
*	No Left or Right Trigger Alignment functionality
*	No DMB Decimation & Split File Save


-----------------------------------------------------
HOW TO INSTALL GAGESCOPE 3.84
-----------------------------------------------------

IMPORTANT NOTE:

BEFORE YOU BEGIN

   Any previous versions of GageScope must be removed 
   before attempting to install GageScope 3.84.

   If Internet Explorer version 4.0 or lower is 
   installed (or if no version of Internet Explorer 
   is installed at all), you must first install 
   Internet Explorer version 5.0 or higher from 
   Microsoft's web site.

   You MUST install the most current CompuScope Driver.  
   Without these drivers,  GageScope will not operate.  
   This should be done before the installation of
   GageScope.  Current drivers may be downloaded from 
   the GaGe website at:
   http://www.gage-applied.com/support/softwares.php



CD-ROM INSTALLATION

   The GaGe CompuScope CD-ROM is equipped with the 
   AutoRun feature which will bring-up the 
   installer's main screen.  If this does not take 
   place, you can start the installer by 
   double-clicking on the Gage.exe item you will 
   find on the CD.  The GageScope installation can be 
   found under the Install GaGe Software option.  
   The Install Software screen has a GageScope 
   Application option that will start the 
   installation process.

   Follow the on-screen instructions to install the 
   software.  The installation program will begin the 
   setup procedure, and you should see a Welcome 
   screen.

   Enter your name and company name in the Customer 
   Information screen.

   GageScope 3.84 is available in 3 different 
   editions; Lite, Standard, and Professional.  You 
   will be asked to select the version that is most 
   appropriate to your needs. You can also select to 
   try the Professional Edition for a 21-day limited 
   time trial. Please note that you will not be able 
   to take advantage of the Professional Edition 
   trial once you have installed the Lite or 
   Standard editions.

   You will need to obtain a License key to proceed 
   with the Installation process. You must register 
   online at
   www.gage-applied.com/support/GageScope_download.php 
   to obtain the GageScope 3.84 software key.  Once 
   you have registered, the software key will be 
   e-mailed directly to you.  A key cannot be 
   obtained by contacting GaGe or its 
   representatives by telephone, fax, or e-mail.

   You will be prompted to enter your software key.

   In Select Components dialog you will be presented 
   with a list of components.  Select or un-select 
   the components you wish to install from those 
   available by clicking in the checkbox next to the 
   item.

   In the Select Program Folder dialog, you may 
   change the folder in which GageScope is installed.

   The default installation directory is:

   C:\Program Files\Gage\GageScope

   Although it is recommended that you accept this 
   default Gage program folder, you may change this 
   directory in the install program if you wish.

   After selecting the Program Folder, the 
   installation will proceed, and you should see the 
   installation progress indicators on your screen.

   Once the installation process is finished, the 
   Setup Complete screen will appear.  Click on 
   Finish to complete the Setup Process.


-----------------------------------------------------
KNOWN INSTALLATION BUGS IN GAGESCOPE 3.84
-----------------------------------------------------

Versions 3.84 and 2.16 cannot be installed and used 
concurrently.  The most-recently installed version 
will be operable (3.84), the older version will 
become inoperable.  Please uninstall any previous 
version before installing a newer version.

Installing version 3.84 will not overwrite versions 
2.24.06, 3.10 or 3.50.  This will show up as two 
separate instances of GageScope in the Control 
Panel's "Add/Remove Programs" list.

Installing version 3.84 will not remove a previous 
installation of GageViewer.exe. GageViewer.exe may 
not function correctly with the new installation and 
should be ignored or erased manually.


-----------------------------------------------------
HOW TO REACH GAGE
-----------------------------------------------------

Comments and suggestions can be addressed to:

Product Manager - GageScope(r) Software
Gage Applied Technologies


In North America:
Tel:    800-567-GAGE
Fax:    800-780-8411

Outside North America:
Tel:    (514) 633-7447
Fax:    (514) 633-0770

E-mail:   prodinfo@gage-applied.com
Web site: www.gage-applied.com